Pitfalls of Protein Extraction by RIPA Buffer – Invent Biotechnologies Inc.

Pitfalls of Protein Extraction by RIPA Buffer

Download as a pdf 

Quanzhi Li Ph.D., Invent biotechnologies Inc

Introduction

Protein extraction using RIPA buffer is a common practice. However due to the lack of comparable method, there is no direct comparison of protein pro les extracted by RIPA buffer and other methods. Here we report a side by side comparison between a rapid (1- 3 min) novel protein extraction kit and

Materials and methods

Proteins were extracted from mouse liver and splenocytes by MinuteTM total protein extraction kit for animal cultured cells/tissues (referred to as Minute kit below) and RIPA buffer (R0278, Sigma). Brie y, samples using Minute kit were prepared according to manufacturer's instruction. There is no insoluble fraction with Minute kit. For RIPA buffer, tissues were homogenized and extracted for 30 min with shaking. The lysates were centrifuged at 12,000xg for 10 min. The residual insoluble fraction of RIPA extraction was further extracted using the Minute kit and analyzed by 12% SDS-PAGE.

Results and discussion

A side by side protein pro le comparison is shown in Figure 1. The protein pro les of the two methods are similar but not identical. Proteins extracted by RIPA buffer contain signi cant less proteins in low molecular weight area (lane 2) but they are signi cantly increased in residual insoluble fraction (Lane 3). Large numbers of protein are found in post-RIPA extraction fractions and the protein pro les in Lanes 2 and 3 are not the same, indicating that signi cant amount of protein is lost to the insoluble fraction and that the protein loss is non-proportional and somewhat selective. The pro les of lost proteins are obviously different in the two samples. The size distribution of lost proteins covers the whole protein spectrum ranging from >120 to <20 KDa. Ngoka (1) compared the protein pro les of RIPA extracted proteins and proteins extracted from the insoluble fractions of breast cancer tissues by mass spectrometry and found that nearly all extracellular matrix (EMC) and many other proteins are exclusively found in the insoluble fractions. EMC proteins are very critical for cancer research (invasiveness and metastasis). Fibronectin was found poorly solubilized in RIPA buffer (2) and altered biochemical pathways with RIPA buffer has also been reported (3). Based on these ndings, it is obvious that the protein pro le extracted by RIPA buffer is incomplete and altered. Serious data interpretation issues could arise for many qualitative and quantitative experiments using RIPA buffer only. Data veri cation by other methods should be considered. In view of the fact that Minute kit can extract proteins from post-RIPA extraction insoluble fraction ef ciently, it is superior to RIPA buffer in terms of completeness of protein pro le, ease of use, speed and performance. For more info visit: inventbiotech.com

References

  1. Lamber CM Ngoka (2008). Proteome Science. 6:1 (1)
  2. Grover A. and Admson ED. (1985). J Biol Chem 260:12252-12258
  3. Deseau et al., (1987). J Cellular Biochem 1987, 35:113-128.