Pitfalls of Protein Extraction by RIPA Buffer

Download as a pdf 

Quanzhi Li Ph.D., Invent Biotechnologies Inc

Introduction

Protein extraction using RIPA buffer is a common practice. However, due to the lack of a comparable method, there is no direct comparison of the protein profile extracted by the RIPA buffer and other methods. Here, we report a side-by-side comparison between a rapid protein extraction kit and RIPA Buffer.

Materials and methods

Proteins were extracted from mouse liver and splenocytes by MinuteTM total protein extraction kit for animal cultured cells/tissues (referred to as Minute kit below) and RIPA buffer (R0278, Sigma). Briefly, samples using the Minute kit were prepared according to the manufacturer's instructions. There is no insoluble fraction with the Minute kit. For the RIPA buffer, tissues were homogenized and extracted for 30 min with shaking. The lysates were centrifuged at 12,000xg for 10 min. The residual insoluble fraction of RIPA extraction was further extracted using the Minute kit and analyzed by 12% SDS-PAGE.

Results and discussion

A side-by-side protein profile comparison is shown in Figure 1. The protein profiles of the two methods are similar but not identical. Proteins extracted by RIPA buffer contain significantly fewer proteins in the low molecular weight area (lane 2), but they are significantly increased in the residual insoluble fraction (Lane 3). Large numbers of proteins are found in post-RIPA extraction fractions, and the protein profiles in Lanes 2 and 3 are not the same, indicating that a significant amount of protein is lost to the insoluble fraction and that the protein loss is non-proportional and somewhat selective. The profiles of lost proteins are obviously different in the two samples. The size distribution of lost proteins covers the whole protein spectrum, ranging from >120 to <20 KDa. Ngoka (1) compared the protein profiles of RIPA-extracted proteins and proteins extracted from the insoluble fractions of breast cancer tissues by mass spectrometry and found that nearly all extracellular matrix (EMC) and many other proteins are exclusively found in the insoluble fractions. EMC proteins are very critical for cancer research (invasiveness and metastasis). Fibronectin was found poorly solubilized in RIPA buffer (2), and altered biochemical pathways with RIPA buffer have also been reported (3). Based on these findings, it is obvious that the protein profile extracted by the RIPA buffer is incomplete and altered. Serious data interpretation issues could arise for many qualitative and quantitative experiments using RIPA buffer only. Data verification by other methods should be considered. In view of the fact that the Minute kit can extract proteins from post-RIPA extraction insoluble fraction efficiently, it is superior to RIPA buffer in terms of completeness of protein profile, ease of use, speed, and performance. 

 

For more info, visit: inventbiotech.com

References

  1. Lamber CM Ngoka (2008). Proteome Science. 6:1 (1)
  2. Grover A. and Admson ED. (1985). J Biol Chem 260:12252-12258
  3. Deseau et al., (1987). J Cellular Biochem 1987, 35:113-128.